Use the following guide to set up a Smart System that consists of a Gateway, at least one thermostat, and at least one wireless StatLink module.
43301 Wireless Gateway included parts:
46801 Wireless Thermostat included parts:
40328 8 Zone Wireless Module included parts:
43302 Wireless Relay included parts:
- Remove thermostat from mounting plate – pull out from bottom.
- Use the included screws to mount the backplate to the wall in the desired location.
- Install the included 4 AAA batteries into the thermostat.
- The thermostat will run through the start up sequence.
- The thermostat is now ready for pairing.
Mount the Wireless StatLink Module using DIN Rail
Mount the Wireless StatLink Module to the Wall
Though the StatLink communicates wirelessly with the thermostats, it does require hard-wiring to any zone actuators, the heat source, pump(s), dew sensors, and changeover valves.
- Wire the actuators to the appropriate zone terminals (see manufacturer instructions for actuator installation procedure).
- Clip the wires into the strain reliefs.
- Wire the heat demand, pump, and optional dew point switch and heat/cool changeover.
- Wire the 24VAC power source (not included)
Follow these procedures for pairing the devices in your Smart System. Depending on the complexity of your heating system, it is recommended that you pair each device at the same time in a single room, labeling each thermostat, WVA, and StatLink to ensure that when they are installed they are installed in the correct location.
For instructions on setting up the thermostat programming click here.
Click here for Troubleshooting