Use the following guide to set up a Smart System that consists of a Gateway, at least one thermostat, a Wireless Valve Actuator, and a Wireless Relay (RX1)
43301 Wireless Gateway included parts:
46801 Wireless Thermostat included parts:
56401 Wireless Valve Actuator included parts:
43302 Wireless Relay included parts:
- Remove thermostat from mounting plate – pull out from bottom.
- Use the included screws to mount the backplate to the wall in the desired location.
- Install the included 4 AAA batteries into the thermostat.
- The thermostat will run through the start up sequence.
- The thermostat is now ready for pairing.
- The valve will take approximately 2 minutes to complete the start up process.
- Once the start up sequence is complete, install the valve onto the actuator – finger tighten the collar only. Using a wrench or other may damage the collar, WVA, or actuator valve.
- Calibrate the WVA to the actuator:
- Press the Open or Close button once.
- The motor will take 1-2 minutes to calibrate to the valve.
- The LED turns off when the valve is calibrated and ready for pairing.
Follow these procedures for pairing the devices in your Smart System. Depending on the complexity of your heating system, it is recommended that you pair each device at the same time in a single room, labeling each thermostat, WVA, and StatLink to ensure that when they are installed they are installed in the correct location.
For instructions on setting up the thermostat programming click here.
Click here for Troubleshooting